IR to RS232 Codes Output Table for RCV-5000 Infrared Receiver

Sanyo DVR3009 Digital Video Recorder

Celadon Inc. 
RCV-5000  IR to RS-232 Output Table
Device: Sanyo DVR3009 Digital Video Recorder
Infrared Remote Control: Philips PRONTO, Niles Intellicontrol
Infrared Code Format: NEC - Device ID: 7B02
Infrared Pronto Data File(s): See "IR Code Read Me - RCV-5000.txt" for complete description
Infrared Receiver: Celadon RCV-5000 Infrared to RS-232 Receiver
RCV-5000 Data File: sanyo2_r.hex
Data: 9600 baud, 8, N, 1 (Selected 9600 from list), HEX Output
Standard Transmit and Receive Pinout
Uses Start and Stop Command for RS-232. Start - F6 and Stop - F7
Programmed Start and Stop around each command.
Sanyo Command Pronto Button RCV-5000 Output
Timer ON/OFF 0 F6,60,F7
Shift <--- 1 F6,53,F7
Shift ---> 2 F6,63,F7
Shift ^ 3 F6,54,F7
Shift v 4 F6,64,F7
Menu 5 F6,74,F7
Shift+/RP UP 6 F6,65,F7
Shift-/RP DOWN 7 F6,66,F7
Security Lock ON 8 F6,69,F7
ACK 9 F6,0A,F7
Play 10 F6,3A,F7
Rev Play/ Search (DVR) 11 F6,4A,F7
NAK 12 F6,0B,F7
Stop 13 F6,3F,F7
Still 14 F6,4F,F7
Clock Adjust 15 F6,E0,F7
Menu Reset 16 F6,E1,F7
Zoom (MPX) 17 F6,85,F7
Status Sense 18 F6,D7,F7
Rec 19 F6,CA,F7
Rec/Dub Request 20 F6,FA,F7
FF/Alarm F 21 F6,AB,F7
Channel 22 F6,8C,F7
Rew/Alarm R 23 F6,AC,F7
Copy 24 F6,8D,F7
OSD/Exit 25 F6,8E,F7
Rec Stop 26 F6,CF,F7
Celadon, Inc.
500 Tamal Plaza, Suite 520
Corte Madera, CA 94925
Sales: (415) 472-1177 x201
Main Tel: (415) 472-1177
Main Fax: (415) 472-1179
sales@manufacture-infrared-remotes.com

Download the Infrared (IR) Code Files for the Pronto Remotes (.ccf and .pcf)


Celadon, Inc. | 58 Paul Drive, Suite D | San Rafael, CA 94903 U.S.A. | Sales: +1 (415) 472-1177 x201 | Fax: +1 (415) 472-1179
© Celadon, Inc. 2024 All Rights Reserved